CISA Domain 5A-2 Practice Test 002

This practice test covers Domain 5 (Protection of Information Assets) Subdomain A-2 (Physical and Environmental Controls) from the CISA exam content outline.

These questions are inspired by the ISACA CISA exam and are designed to help you test your knowledge of information systems auditing, governance, risk management, IT operations, business resilience, and information asset protection.

These are not official exam questions or brain dumps. They are original scenario-based questions created to reflect the audit judgment, control evaluation, and risk-based decision-making skills tested in the CISA exam.

Note: CISA and Certified Information Systems Auditor are registered trademarks of ISACA. This content is not affiliated with or endorsed by ISACA.

To choose CISA practice tests based on specific domains and subdomains, click that link.

CISA 5A-2 Physical and Environmental Controls Practice Test 002
10 questions • Single best answer
Question 1
A state university's research computing center houses clustered servers in a raised-floor room protected by a wet-pipe sprinkler system mounted directly above the equipment racks. Facilities staff explain that the system was selected because it was inexpensive and has never discharged accidentally. Which recommendation should the IS auditor make?
    Question 2
    An IS auditor at a regional hospital is testing whether physical access to the data center is restricted to authorized personnel. Management provides the access control policy and a list of approved badge holders signed by the IT director. Which of the following would provide the BEST evidence that the control is operating effectively?
      Question 3
      During an audit of a government agency's primary data center, an IS auditor identifies several physical and environmental weaknesses. The agency processes benefit payments that must be issued within 24 hours, and the facility currently has no alternate processing site or reciprocal agreement. Which finding is MOST significant?
        Question 4
        An IS auditor reviewing a logistics company's server room finds that temperature and humidity sensors send alerts to a shared mailbox. Alert history shows multiple high-temperature warnings during the past quarter with no recorded response, ticket, or follow-up by any team. What should the IS auditor do FIRST?
          Question 5
          A financial services firm installed a mantrap at its data center entrance after an unauthorized contractor followed an employee inside. During testing, an IS auditor observes that the interlock between the two doors has been disabled so both can open simultaneously, reducing delays during shift changes. Which conclusion is MOST appropriate?
            Question 6
            A healthcare software-as-a-service provider hosts its production servers in a third-party colocation facility. While planning an audit of physical and environmental controls, the IS auditor learns that the provider's contract does not grant on-site inspection rights, and the colocation vendor has declined a site visit. Which approach is MOST appropriate?
              Question 7
              An internal audit of a manufacturing company finds that data center access reviews are performed by the facilities manager, who also administers the badge system and grants access. The CIO considers this efficient because the facilities manager knows all staff personally. Which recommendation is MOST appropriate?
                Question 8
                An IS auditor at an electric utility is assessing whether backup power will sustain the grid control center during an extended outage. Management provides monthly generator maintenance records showing oil changes, battery checks, and visual inspections, all completed on schedule by the vendor. Which additional procedure would provide the BEST assurance?
                  Question 9
                  In a prior-year audit of an insurance company, the IS auditor reported that the server room lacked water detection beneath its raised floor. Management's response stated that sensors were installed in the second quarter. During follow-up, what should the IS auditor do to BEST confirm that the risk has been addressed?
                    Question 10
                    A retail chain plans to relocate its primary data center to a leased building. The IS auditor reviewing site selection notes that the preferred location is in a designated flood zone, below ground level, and adjacent to a chemical storage warehouse. Which action is MOST appropriate for the IS auditor?