CompTIA Network+ Practice Test for Subdomain 5.2 #02

Welcome to today’s CompTIA Network+ practice test!

This practice test uses our new UI!

Today’s practice test is based on Subdomain 5.2 (Given a scenario, troubleshoot common cabling and physical interface issues) from the CompTIA Network+ N10-009 objectives.

This beginner-level practice test is inspired by the CompTIA Network+ (N10-009) exam and is designed to help you reinforce key networking concepts on a daily basis.

These questions are not official exam questions, nor are they brain dumps, but they reflect topics and scenarios relevant to the Network+ certification. Use them to test your knowledge, identify areas for improvement, and build daily cybersecurity habits.

Note: CompTIA and Network+ are registered trademarks of CompTIA. This content is not affiliated with or endorsed by CompTIA.

To choose CompTIA Network+ practice tests based on specific domains/subdomains, click that link.

Recommended read: Ultimate CompTIA Network+ Study Guide (2026)

CompTIA Network+ Practice Test of the Day 260530
10 questions • Single best answer
Question 1
A junior network engineer at a manufacturing plant notices two Ethernet cables run parallel for over 30 feet inside a cable tray. Users report random disconnections and error frames on both segments. A cable tester confirms all wires are properly terminated with no open or short circuits. What is the most likely cause?
    Question 2
    A field technician connects a fiber uplink between two switches and no link light appears on either end. The cable is visually intact and fully seated. The technician swaps the fiber strands at one end of the cable, and both link lights immediately come up. What was the problem?
      Question 3
      A network technician installs a Cat6 run of 110 meters between a remote access point and the IDF. The AP associates to the wireless controller but clients experience consistently poor throughput and high error rates. No physical damage is visible on the cable. What is the most likely cause?
        Question 4
        A technician uses a cable tester on a dead network drop and finds that some conductors show continuity while one wire within a pair shows no connectivity at either end. What physical condition does this test result indicate?
          Question 5
          During a structured cabling installation, a technician crimps an RJ-45 connector onto a Cat6 patch cable. The connection is intermittent under movement. Upon inspection with a magnifier, several pins inside the connector are not fully driven down through the wire insulation. What is causing the problem?
            Question 6
            A cable tester on a newly installed Cat5e run passes all continuity tests but fails the wire map. The report shows that one wire from pair 2 is swapped with a wire from pair 3 at both ends. What condition is indicated?
              Question 7
              After installing a fiber run from an IDF to an MDF in a hospital, a technician measures high optical insertion loss at the connection point using an optical power meter. Cleaning both fiber end faces with an approved lint-free tool and re-testing shows normal signal levels. What was the root cause?
                Question 8
                A technician installs a new SFP module in a core switch to bring up a fiber uplink. The switch recognizes the module, but the link does not come up. The remote switch shows the same behavior. Both fiber runs test clean and TX/RX polarity is correct. What should the technician verify next?
                  Question 9
                  A network technician at a branch office punches down cables on a patch panel using the T568B wiring standard, but the patch cables connecting the panel to switches were factory-terminated using T568A. Users on those drops experience complete connectivity failure. What is the root cause?
                    Question 10
                    A data center technician measures receive power on a new fiber run at -19 dBm. The SFP datasheet specifies a minimum acceptable receive power of -14 dBm. The cable has no visible bends or damage. What is the most likely cause?